We are Taizhou Yingshi Environmental Protection Equipment Co.,LTD we are major in manufacturing all type air cooler, with the advantage that we have the production line, designing, moulding and manufacturing all by ourselves.
1. The working concept of the down discharge axial evaporative air cooler
Using the circulating pump to pumping the water out of the tank, and trough the water distribution system spray evenly on the evaporation filter layer, the outdoor hot air enter the evaporation cooling medium, inthe medium(honeycomb filter layer of special material, so that better cooling efficiency ) to proceeding the fully heat exchange with water.
Through the evaporation wet curtain, which the transfer area is several times lager than the surface, to absorb a lot of heat, so as to achieve the purpose of cooling. The cool and clean air cooled by water evaporation absorbs the heat, pressurized by the low-noise fan into the room, and make the indoor hot air exhaust to the outside, and achieve the purpose of cooling the indoor air.
2. The specification of the down discharge axial evaporative air cooler
Air flow 18000m³ /h
Voltage 3 phase, 380V/50Hz
Single phase 220V, single speed
Variable frequency with the inverter
Fan type Axial air cooler
Power 1.1KW
Noise ≤ 79dB
Water tank 20L
Controller Manual controller 1 speed
Remote controller 12 speed with the inverter
Wind outlet typeTop, down discharge
Size 1.08*1.08*0.95m
Weight 60 KG
Usable area 100-150m2
Name evaporative air cooler
HS code 847960000
3. The adescription of the parts of the down discharge axial evaporative air cooler
Casing: Modified PP plastics adopted, high strength, not easy deformation, anti-ultraviolet ray and ageing resistance
Blower fan: Novel wind blades adopted, sufficient air quantity, high pressure, and effective noise inhibition
Motor: Full aluminum casing adopted, good appearance, light weight, quick heat dissipation, high efficiency, dust and moisture prevention, high quality dual sealed bearings equipped, and high safety and maintenance free
Cooling pad: Imported paper adopted, good water absorption, high evaporation efficiency, specially formulated glue, greenness and environmental protection, good viscosity, no degumming even being soaked all the year around, and a long service life
Water pump: A permanent magnetism footed pump, high efficiency, and overcoming the defect of easy damage caused by water deficiency, idling and scaling
Controller: Manual single speed controller or LCD controller, and also we can use the frequency inverter can control 12 speed also with the remote controller
With an outside dust screen, this can be easily removed and cleaned.
4. Wind outlet type of the air cooler
Top dicharge,
Down discharge
Side discharge
Airflow |
18000m³/h |
Fan type |
Axial |
Power |
1.1KW/1.5KW |
Voltage |
220V/380V |
Frequency |
50HZ /60hz |
Phase |
1/3 |
Dimension |
1080*1080*950mm |
Air pressure |
195Pa |
Speed |
1/12(Variable-frequency Drive ) |
Cooling area |
100-150 m2 |
Noise |
≤70db |
Water consumption |
10-15L/h |
Water tank |
20L |
Weight |
70KG |
Loading quantity
(20'/40'/40HQ) |
20/40/44 |
inlet/outlet |
Manual/Auto |